This pump is only suitable for membranes of 50-90 USG due to the flow rate of the pump and depending on the efficiency of the membrane/water temperature.
Calculation
1.2 lts/min = 1728 lt/day = 455 USG/day
Flow rate must account for both collected and rejected water volumes through the RO unit.
- If 4:1 reject rate = 455/5 = 91 USG
- if 5:1 reject rate = 455/6 = 76 USG
We recommend that the pump is not used with any membrane over 100 USG/day as it will reduce the flow rate to the RO and will reduce the efficiency.
The pressure of 125PSI is the maximum pressure that the pump can produce when restricted however the larger the membrane the easier the water will flow and the less pressure will be produced.
Caution
NEVER DEAD HEAD THE PUMP FOR ANY TIME AGAINST A CLOSED SOLENOID OR CLOSED SHUT OFF VALVE AS THIS WILL DAMAGE THE DIAPHRAGM. IF THIS DOES HAPPEN, THEN A REPLACEMENT HEAD IS AVAILABLE.
Flow Rate (open flow): 1.2lts/min
Pressure: 125 PSI (9 BAR)
Voltage: 24V